Brotie Zirconia Online Process Trace Oxygen Instrument
Reference FOB Price: | US $100.00-1,000.00 / Piece |
---|---|
Min. Order: | 1 Piece |
Customized: | Customized |
---|---|
Portable: | Portable |
Gas: | O2 |
Type: | Thermal Conductivity Gas Analyzer |
Measure Range: | 0-100ppm, 0-1000ppm, 0-1%, 0-25% O2 |
Accuracy: | ≤±2% in Fs Range |
Basic Info
Model NO.
100
Response Time
90% of Final Fs Reading ≤5 Seconds
Display Resolution
0.1ppm
Repeatability
≤±1%
Ambient Temp
0c-+60c
Sampling Gas Flow
200-400ml/Min
Sampling Gas Pressure
0.035MPa≤inlet Pressure≤0.21MPa
Transport Package
Carton
Specification
CE
Trademark
BROTIE
Origin
China
HS Code
9027100090
Production Capacity
10000sets/Year
Product Description
Zirconia Trace Oxygen Analyzer
Features
* New style zirconia oxygen sensor, long life, high precision and fast response
* With man-machine conversation menu, easy to operate.
* Inner special gas-route protects the sensor when it exposures in the air for a long timeby out of power or cutting off the gas-route automatically.
* Setting Upper and lower alarm values freely during the measure ranges.
* 4-20mA signal output
* One standard RS232C or RS485 interface
Technical Specifications
Features
* New style zirconia oxygen sensor, long life, high precision and fast response
* With man-machine conversation menu, easy to operate.
* Inner special gas-route protects the sensor when it exposures in the air for a long timeby out of power or cutting off the gas-route automatically.
* Setting Upper and lower alarm values freely during the measure ranges.
* 4-20mA signal output
* One standard RS232C or RS485 interface
Technical Specifications
Measure Range | 0-100ppm, 0-1000ppm, 0-1%, 0-25% O2 |
Accuracy | ≤ ± 2% in FS range |
Response Time | 90% of final FS reading ≤ 5 seconds |
Display Resolution | 0.1ppm |
Stability | Zero drift ≤ ± 2% of FS/7d |
Span drift | ≤ ± 2% of FS/7d |
Repeatability | ≤ ± 1% |
Ambient Temp | 0~+60C |
Sampling Gas Flow | 200~400ml/MIM |
Sampling Gas Pressure | 0.035MPa≤ Inlet pressure≤ 0.21Mpa |
Power Supply | 220± 10% VAC, 50/60Hz, power loss≤ 20VA |
Measure Medium | N2, inert gases |
Contact Capacity | AC125V 0.3A, AC110V 0.5A, DC24V 3A |
Sensor Life | 24 months at 25C and 1 ATM |
Warranty | 12 months analyzer; 12 months sensor |
Weight | 3kg |
Installation Dimension | 133mm× 133mm× 250mm (W× H× D) |