Product Description
BROTIE High Purity Oxygen Analyzer(Economical model)
Features:
- New pattern, long-life, with long service life, fast response and high sensitivity;
- Sensor designed by ion current technology;
- Menu locking function provided, avoid the misoperation to change the parameters on the analyzer;
- Automatically memorizing system equipped, operation time of the analyzer will be recorded automatically ;
- Compact size, simple construction, easy on operation and after service;
Industries Served:
It can be used in high purity oxygen production(PSA, VPSA, Cryogenic), metallurgy, health, petrochemicals, and power electronics industries.
Specifications:
Range: |
10.00%-96.00%, 10-99.00%(special model) |
Accuracy: |
±2% of FS range, ±0.2% of 80-99% |
Repeatability: |
±1% of FS range |
Principle: |
Ion current technology (can service in Air and inert gases, not corrosive gases.) |
Sample gas flow speed: |
400~600ml/min |
Stability: |
±1% of FS/7d |
Response time: |
90% of FS reading in 60 seconds |
Power supply: |
220V±10%, 50/60Hz |
Signal outputs: |
4-20mA |
Expected analyzer life: |
More than 5 years (in normal condition) |
Expected sensor life: |
2-3 years (in normal condition) |
Installing dimension: |
W×H×D=150mm*74mm*167mm |
BROTIE High Purity Oxygen Analyzer(Professional model)
Features:
- New pattern, long-life, conversion ion current tester with fast response and high sensitivity;
- A standard RS232C interface;
- Setting alarm value and contact output value arbitrarily;
- High precision, automatic temperature compensation, eliminating the impact of environmental temperature;
- Setting upper and lower alarm values arbitrarily during the measurement range;
Industries Served:
It can be used in high purity oxygen production, metallurgy, health, petrochemicals, and power electronics industries.
Specifications:
Range: |
10-99.99%/50-99.99%/90-99.99%/97%-99.99%O2;auto-ranging |
Accuracy: |
±0.5% of FS range, ±0.1% of 90-99.99% |
Repeatability: |
Cv≤0.5% |
Preheating time: |
300s |
Sample gas flow speed: |
150~300ml/min |
Stability: |
zero drift ≤0.5% of FS/7d , span drift ≤0.5% of FS/7d |
Response time: |
90% of FS reading in 15 seconds |
Sensitivity: |
0.01% O2 |
Power supply: |
85-265 VAC, 50/60Hz, power loss≤6w |
Signal outputs: |
4-20mA or 0-5V DC isolated |
Contact capacity: |
125VAC 0.3A, 110VDC 0.3A, 30VDC 1A |
Expected sensor life: |
3 years (in normal condition) |
Installing dimension: |
W×H×D=92mm*92mm*110mm |

Certifications

Packaging & Shipping

Company Profile